Disposal of waste batteries
Auther: Pubdate:2020-06-03
There are two main types of lead-acid battery manufacturers that deal with used batteries, one is a lead-acid battery with an electrolyte, and the other is a maintenance-free battery. The service life of the battery not only depends on the structure and quality of the battery, but also is closely related to the use and maintenance. The service life of general batteries is about 5-8 years, if properly maintained, it can reach 8-12 years. It is very necessary to maintain the battery once during the season change.
   Maintenance-free batteries are completely sealed without adding distilled water and adjusting the concentration of the electrolyte, and generally no electrolyte will spill onto the battery surface. Its maintenance is very simple. It mainly checks whether there is liquid leakage, cleans the dirt on the surface, handles the oxides of the positive and negative poles, fastens the clamps of the two poles, and observes the color of the battery eye. The color of the electric eye is green for sufficient power; black is for insufficient power and needs to be recharged; gray or light yellow is for insufficient electrolyte, because the maintenance-free battery cannot be filled, the battery should be replaced immediately.
 
Disposal of waste batteries
 
The maintenance of waste lead-acid batteries is more troublesome. In addition to the maintenance-free items mentioned above, the lead-acid battery factory also needs to pay attention to the following two aspects: First, check and adjust the height and concentration of the electrolyte, and the electrolyte. The height should be between high and small. Too low will reduce the capacity of the battery and cause the electrode plate to vulcanize. Too high will overflow to the surface of the battery to corrode the pole pile, wire and car body. The concentration of the electrolyte has a great influence on the working condition of the battery. In our northeast winter, the sulfuric acid concentration of the electrolyte should be adjusted to 1.28 g/ml. Note that the concentration measurement and adjustment must be performed when the battery is fully charged; two It is necessary to clean the exhaust pipe, keep the exhaust pipe well ventilated, and exhaust the exhaust gas generated in the charging process in time, otherwise it will cause the electrolyte to overflow from the filling hole, and even cause the battery to explode.
 
  The above is the relevant information summarized by the editor of the solar colloid battery manufacturer Kang Lida. I hope it will be helpful to you. If you want to know more information, you can contact us or visit our official website: see more relevant information