Disposal methods for used batteries
Auther: Pubdate:2019-09-11
There are two main types of lead-acid battery manufacturers dealing with used batteries, one is a lead-acid battery with electrolyte, and the other is a maintenance-free battery. The length of battery life depends not only on the structure and quality of the battery, but also on the application and maintenance. Generally, the service life of the battery is about 5-8 years. If it is properly maintained, it can reach 8-12 years. It is necessary to maintain the battery once during the season.
 
 
The maintenance-free battery is completely sealed without adding distilled water and adjusting the concentration of the electrolyte. Generally, no electrolyte overflows onto the surface of the battery. Its maintenance is very simple, mainly to check whether there is leakage, clean the surface of the dirt, handle the oxides of the two poles, tighten the clamps of the two poles and observe the color of the battery eye. The color of the electric eye is green for sufficient power; black is insufficient for power and needs to be recharged; gray or light yellow is insufficient for electrolyte. Since the maintenance-free battery cannot be filled, the battery should be replaced immediately.
 
Disposal methods for used batteries
 
The maintenance of lead-acid used batteries is more troublesome. In addition to the above-mentioned maintenance-free battery maintenance items, the lead-acid battery factory should pay attention to the following two aspects: First, check and adjust the height and concentration of the electrolyte, the electrolyte The height should be between high and small. Too low will reduce the capacity of the battery and cause the plate to vulcanize. If it is too high, it will overflow to the surface of the battery to corrode the poles, wires and body. The concentration of the electrolyte has a great influence on the working condition of the battery. The sulfuric acid concentration of the electrolyte in our northeast winter should be adjusted to 1.28 g/ml. Note that the concentration measurement and adjustment must be carried out when the battery is fully charged; It is necessary to clean and unblock the exhaust pipe, keep the exhaust pipe well ventilated, and discharge the exhaust gas generated during the charging process in time. Otherwise, the electrolyte will overflow from the liquid-filling hole, which may even cause the battery to explode.
 
 
The above is the information compiled by the solar gel battery manufacturer Kang Lida, I hope to help you, if you want to know more information, you can contact us, or visit our official website: see more information.